Vent-L Thermo Valve for Irrigation K01, 1/2" Opening Adjustment from 50-82°F

Vent-L Thermo Valve for Irrigation K01, 1/2" Opening Adjustment from 50-82°F
Vent-L Thermo Valve for Irrigation K01, 1/2" Opening Adjustment from 50-82°F
Vent-L Thermo Valve for Irrigation K01, 1/2" Opening Adjustment from 50-82°F
Vent-L Thermo Valve for Irrigation K01, 1/2" Opening Adjustment from 50-82°F
Vent-L Thermo Valve for Irrigation K01, 1/2" Opening Adjustment from 50-82°F
Vent-L Thermo Valve for Irrigation K01, 1/2" Opening Adjustment from 50-82°F
$17
Quantity
pcs.
Vent-L Thermo Valve for Irrigation K01, 1/2" Opening Adjustment from 50-82°F

The thermocrane for watering "Vent-L" K01, with the valve 1/2 inch. It works on the ambient temperature, allows you to save water and prevent excess humidity, with any dosed (drip, portioned, etc.) watering. The temperature of adjusting the water supply is from +10 to ° C + 28 ° C, the hysteresis (full operation) of the full opening and closing of the thermocrane 2.5 ° C, the operating temperature is from + 1 ° to C + 80 ° C. Storage temperature (without water in the valve) -30 ° to C + 80 ° C. The maximum pressure in the valve is 10 Bar. Maximum thermal head stem pressure 16 Bar.



Adjusting the temperature of the water supply 10-28 "C
Water supply thread,entrance - 1/2 "internal
Exit -1/2 "external thread
Box dimensions, cm -10 * 10 * 6
Weight Assy -0.38kg
  • 1 Vent-L Thermo Valve for Irrigation K01, 1/2" Opening Adjustment from 50-82°F The thermocrane for watering Vent-Lgreen K01, with the valve 1/2 inch. allows to save water and to prevent the processes of excessive rotting, diseases on the soil surface for any dosed (drop, portioned, etc.) watering. It can be integrated into any watering systems both in the greenhouse and outside it. Vent-Lgreen allows you to turn off watering when the temperature becomes low, during rain or at night, when humidity is high (for example, in a greenhouse with closed vents), and turn on watering when the temperature becomes high and the sun begins to evaporate moisture from the soil surface (for example, in a greenhouse when the vents are automatic vent opener). The opening and closing temperature of watering is adjustable in the range from 10 to 28 ° C (50-82°F). The temperature of adjusting the water supply is from +10 to ° C + 28 ° C, the hysteresis (full operation) of the full opening and closing of the thermocrane 2.5 ° C, the operating temperature is from + 1 ° to C + 80 ° C. Storage temperature (without water in the valve) -30 ° to C + 80 ° C. The maximum pressure in the valve is 10 Bar. Maximum thermal head stem pressure 16 Bar. Adjusting the temperature of the water supply 10-28 "C Water supply thread,entrance - 1/2 "internal Exit -1/2 "external thread Box dimensions, cm -10 * 10 * 6 Weight Assy -0.38kg
Vent-L Thermo Valve for Irrigation K01, 1/2" Opening Adjustment from 50-82°F
$17